• XK-M415E radio enclosure
IP MESH RADIO

XK-M415E MIMO Mesh Video and Data Radio

XK-M415E connects network video, serial data and SBUS control through a MIMO mesh radio. Its Ethernet and UART interfaces suit projects bringing several terminal types onto one node, with a listed nominal 24 V supply configuration.

  • Three Ethernet interfaces, three TTL/RS232 UART interfaces, another selectable serial interface and one SBUS interface support different terminal connections.
  • 20–28 V DC input, nominal 24 V; power consumption is ≤65 W at 40 dBm RF output.
  • 125 × 95 × 42 mm dimensions and device weight ≤650 g support platform-space and weight checks.
  • Xingkai specifies the radio configuration and connected accessories around the equipment in your project.

XK-M415E MIMO Mesh Video and Data Radio Overview

XK-M415E brings encoded network video and control-terminal data into the same mesh-radio node. Multiple Ethernet and UART interfaces, together with SBUS, let the integrator connect different types of equipment without describing every terminal as an Ethernet device.

The listed 1.4 GHz configuration has two adjustable 40 dBm RF branches, a 20–28 V DC input and nominal 24 V supply. The ≤65 W power-consumption entry is tied to 40 dBm RF output. These figures help define the electrical and mechanical allowance for a node before the platform installation is finalised. The device-weight entry describes the radio; the platform allowance also needs the chosen antenna, cable and mounting arrangement.

Technical Specifications

ParameterListed configuration
Frequency range1420–1530 MHz; listed configuration
RF output2 × 40 dBm, adjustable
DC input20–28 V; nominal 24 V
Power consumption≤65 W at 40 dBm RF output
Dimensions125 × 95 × 42 mm
Device weight≤650 g
Data interfaces3 × ETH; 3 × UART (TTL/RS232); 1 × UART (RS232/RS485/RS422); 1 × SBUS
Channel bandwidth3 / 5 / 10 / 20 MHz
ProtocolIEEE 802.3; transparent serial data
Operating temperature−30 to +60 °C
Storage temperature−40 to +75 °C
Network layoutsDistributed centreless point-to-point, point-to-multipoint, relay and mesh networking

Connections and Integration

M415E lists three Ethernet ports, three TTL/RS232 UARTs, one RS232/RS485/RS422 UART and SBUS. List the video, telemetry and control terminals by interface so Xingkai can assign the required ports and harness branches for one node.

Network-video sources use Ethernet; serial terminals must match the selected UART level. Xingkai checks the proposed allocation and relay layout, with any customer-owned encoder or cable identified separately. This defines the connection scope without treating every UART as the same interface.

XK-M415E radio enclosure
CONFIGURATION & SUPPLY

Configure and Order Your Mesh Nodes

Describe the cameras or encoded-video sources and each control-data interface at a node. Xingkai uses those connections, the available DC supply and required node quantities to specify the XK-M415E configuration and quotation.

Confirm the supplied configuration, quantities and delivery terms before ordering. Xingkai supplies and dispatches according to the agreed order.

Describe the project

Send the Ethernet-video sources, serial terminals and SBUS equipment for the M415E port allocation, with the available 20–28 V supply and radio quantities. Identify any encoder and harness you will provide.

Receive the configuration and quotation

Xingkai checks the port allocation and 20–28 V radio-power arrangement against the ≤65 W at 40 dBm reference, then quotes the M415E version and required connection accessories. The equipment list separates customer-owned encoders and cables from the supplied items.

Confirm the order

Agree on the configuration, quantities and delivery terms.

Supply and dispatch

Xingkai supplies and ships according to the confirmed order.

FAQs

Do three Ethernet ports establish three isolated camera networks?

No network-isolation behaviour is established by the M415E three-port entry. If cameras or other terminals must remain on separate networks, describe the required separation and traffic paths. Request the port behaviour for the supplied configuration and identify any separate network equipment needed. Three available connections are not, by themselves, evidence that a managed switch, VLAN arrangement or isolated network service is included.

What if two terminals both require RS485?

Flag that requirement before choosing the M415E harness. The listed structure has three TTL/RS232 UARTs and one UART with RS232/RS485/RS422 choices; it does not establish two independent RS485 connections. Provide both terminals’ specifications and request an explicit connection arrangement for them. If additional interface equipment or another configuration is needed, have it identified separately rather than counting all four UARTs as RS485 ports.

Can a second mesh radio from another supplier join the network?

The same frequency band is insufficient to establish pairing. Identify the exact radio model, firmware, waveform and network settings already installed. Xingkai checks the proposed arrangement when specifying another node; cross-brand operation is not implied by the term MIMO mesh.

Does the power-consumption rating include the camera and encoder?

The ≤65 W entry at 40 dBm RF output is the radio's listed consumption condition. It does not establish the load of all connected equipment. Budget the camera, encoder and other terminals separately against the supply used for the installation.

What must I specify when ordering a relay network?

List the endpoint and relay radio counts separately, and identify the terminals and accessories at each location. State the traffic directions and intended relay arrangement. Xingkai then identifies the radio quantities and configuration in the quotation instead of treating one unit as a complete network.

Compare Related Models

  • XK-F366 radio enclosure

    Vehicle mesh-radio configuration with an 18–32 V DC input; compare its supply and mounting requirements with your installation.

    Appearance reference; the supplied hardware configuration is confirmed in the quotation.

  • XK-F367 radio enclosure

    Vehicle mesh radio with two 20 W RF branches; compare the 18–32 V DC configuration and its electrical load.

    Appearance reference; the supplied hardware configuration is confirmed in the quotation.

  • XK-M372 interface panel detail

    Compare XK-M372 for projects considering a 5 GHz network node.

    Interface detail shown for reference. The pictured label is not a power specification for the supplied configuration.

  • XK-F360 backpack radio enclosure with antennas

    Backpack mesh-radio form for projects considering a portable node rather than a vehicle installation.

Request a Configuration Quote for XK-M415E

Send your Ethernet-video, UART and SBUS terminal requirements, available DC supply, node layout and radio quantities. Xingkai will check the XK-M415E configuration and quote the radios and required accessories.

Wide Contact Form